GLOBESERVER SWITCH SETTINGS

Each GlobeServer connected to the TwinSync card must have a unique address. Each line supports four addresses. Line P1 supports GlobeServer addresses 1, 3, 5, and 7 while line P2 supports GlobeServer addresses 2, 4, 6, and 8. ("P1" and "P2" is marked on the TwinSync card endplate).

1
2
3
4
5
6
7
8
Globeserver Address
X
X
DOWN
DOWN
X
 
S1
S2
S3
On
Off
Off
Unit - 1
 
Off
On
Off
Unit - 2
On
On
Off
Unit - 3
Off
Off
On
Unit - 4
On
Off
On
Unit - 5
Off
On
On
Unit - 6
On
On
On
Unit - 7
Off
Off
Off
Unit - 8

Switch bits 1,2 and 3 of the DIL switch on the top surface of the GlobeServer unit are used for selecting GlobeServer Address.

The GlobeServer may be connected to the TwinSync card using one of four different interfaces.

  • RS485 MultiDrop For local connections up to 1200 Metres. Two wire connection. Line speeds from 250Kbps to 1Mbps. Four GlobeServer units may be connected to one line. (STANDARD MODE
  • RS422 Point to Point For Leased line X21 type interface (Kilostream synchronous 64Kbps). A maximum of two GlobeServer units per line may be used, supporting 16 ports at a remote location. On an ISDN circuit only ONE GlobeServer may be used per line, supporting 8 ports plus a parallel* port at a remote location. 
  • RS232S Point to Point For Leased or dial up line using V34 or faster Synchronous modems. (14K4..28K8bps). Only one GlobeServer unit may be attached - supporting 8 ports plus a parallel* port at a remote location.
  • RS232A Point to Point For Leased or dial up line using Async modems capable of supporting 38K4..57K6bps connection speeds. Only one GlobeServer unit may be attached - supporting 8 ports plus a parallel* port at a remote location.

            (*Parallel Printer support is dependent upon the Operating System driver support.)

For normal use around an office or factory site the standard two wire RS485 mode is recommended. If the distance of the furthest GlobeServer unit on the line is less than 360 Metres then the 1Mbps speed may be selected for optimum throughput.

The GlobeServer system will also support a GlobeServer unit in distant locations (greater than 1200 Metres via leased lines or dial up modems. NOTE other than Kilostream circuits, a line configured to operate over a leased line or modem may only have one GlobeServer unit attached to that line.

Each of the two TwinSync lines may be configured independently. It is possible to configure line P1 for RS485 - 1Mbps operation with one or more GlobeServer units attached while line P2 is configured for RS232 ASYNC use via a dial up modem with one GlobeServer unit attached at the remote end.

Switch bits 4,5 and 6 on the base surface of theGlobeServer unit are used for selecting Line Mode.
 
1
2
3
4
5
6
7
8
x
x
x
Globeserver Line Mode
Down
x
     
Usage
S4
S5
S6
Mode
Speed
Local up to 360 Meters
Off
Off
Off
RS485
1Mbps
Local up to 1200 Meters
On
Off
Off
RS485
250Kbps
Remote X21 (ISDN/Kilostream)
Off
On
Off
RS422
64 Kbps
Reserved
On
On
Off
-
-
V24 Remote Synchronous Link
Off
Off
On
RS232
144Kbps
V24 Remote Asynchronous Link
On
Off
On
RS232
384Kbps
V24 Remote Asynchronous Link
Off
On
Off
RS232
576 Kbps
Reserved
On
On
On
-
-

NOTE If the GlobeServer is to be used for an X21 connection (RS422 Synchronous - Kilostream or ISDN) then the user should check that the TwinSync card jumpers are set correctly.

When a line is configured for RS485 Multidrop operation the GlobeServer attached to end of the line must have its line termination circuit enabled. The other GlobeServer units on the line must have their termination circuitry disabled.
 
SW1
SW2
SW3
SW4
SW5
SW6
SW7
SW8
X
X
X
X
X
X
X
 
 
Description
Termination
Disable Line Termination Circuitry in Globeserver
Disable
Off
Enable Line Termination Circuitry in Globeserver
Enable
On

For normal operation all diagnostic modes should be OFF. Diagnostic modes are disabled when Switch 7 is On.
  
1
2
3
4
5
6
7
8
X
X
X
X
X
X
Diagnostics
X
     
Diagnostic Modes
S7
Disabled (Setting for NORMAL Operation)
Off
User Diagnostic Test Mode
On

Back


IT Factor Ltd t/a TCL
24 Thatcham House
Turners Drive, Thatcham
Berkshire, RG19 4QD, England

Tel: + 44 (0) 1635 876754
Fax: + 44 (0) 1635 871739
sales@TheTCL.com